SYSTEM OVERVIEW系统说明 · SYSTEM RELATIONSHIPS

Understand each role before choosing equipment.先了解各类设备的作用,再确定系统配置。

See how isolation, monitoring, fault location and alarms relate. The project electrical design determines the final topology and equipment selection.了解隔离、监视、故障定位和报警设备如何配合。最终系统结构和设备选型应由项目电气设计确定。

SYSTEM RELATIONSHIPS04 + 01BAUSENT / MEDICAL POWER博圣特 / 医疗供电

01 / HOW THE PRODUCTS WORK TOGETHER设备如何配合

Four related functions across one medical electrical system.四类设备协同构成医疗电气系统。

Isolation, monitoring, fault location and alarms work together around defined circuits and the people who use the system.隔离供电、绝缘监视、故障定位和报警围绕明确的供电回路与使用人员协同工作。

01POWER SUPPLY隔离供电

Isolation transformer & distribution隔离变压器与配电

The transformer supplies the isolated circuit defined by the project design. Downstream distribution serves the designated rooms and loads.隔离变压器为项目设计确定的回路供电,下游配电再连接指定房间和用电设备。

View product details查看产品详情↗
02INSULATION CONDITION绝缘状态

Insulation monitoring绝缘监视

An insulation monitor observes the isolated circuit it is connected to. Alarm thresholds and signals depend on the selected model and project design.绝缘监视仪监测接入的隔离回路。报警阈值和输出信号以所选型号及项目设计为准。

View product details查看产品详情↗
03FAULT INVESTIGATION故障排查

Fault location故障定位

When an insulation alarm occurs, fault-location equipment can help identify the affected outgoing circuit, depending on the selected system.发生绝缘报警后,故障定位设备可帮助查找相关出线回路,具体能力取决于所选系统。

View product details查看产品详情↗
04ALARM DISPLAY报警显示

Local & central alarms本地与集中报警

Alarm information should appear where the intended staff can see and respond to it. Signal sources and display locations are defined by the project.报警信息应显示在相关人员能够查看和处理的位置。信号来源和显示位置由项目确定。

View product details查看产品详情↗
UPS

02 / A SEPARATE BACKUP SUPPLY独立的后备电源

UPS backs up the loads specified for the project.UPS 按项目要求为指定设备提供后备供电。

UPS serves designated loads through a separate backup branch. The project load list defines capacity, backup time, bypass and source-transfer requirements.UPS 通过独立后备支路为指定设备供电。项目负载清单明确容量、后备时间、旁路方式和电源切换要求。

View UPS details查看 UPS 详情↗

03 / QUESTIONS TO CONFIRM项目需确认的问题

Set the boundaries before selecting equipment.选型前,先明确系统边界。

04 / OFFICIAL STANDARD EXTRACTS标准原文摘录

Standard excerpts.标准摘录。

UL 1047 · Ed. 7 · 2025

Isolated Power Systems EquipmentIsolated Power Systems Equipment(隔离电源系统设备)

“isolated power systems equipment rated 600 Vac or less”“额定电压 600 Vac 或以下的隔离电源系统设备”

UL 1022 · Ed. 6 · 2025

Line Isolation MonitorsLine Isolation Monitors(线路隔离监视器)

“dynamic line isolation monitors and related supplementary indicating units”“动态线路隔离监视器及相关辅助指示单元”

IEC 61557-8:2014 · Ed. 3

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems低压配电系统(交流电压不超过 1 000 V、直流电压不超过 1 500 V)的电气安全 — 保护措施的测试、测量或监测设备 — 第 8 部分:IT 系统用绝缘监测设备

“insulation resistance RF to earth of unearthed a.c. IT systems”“未接地交流 IT 系统对地绝缘电阻 RF”

IEC 61557-9:2023 · Ed. 4

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems低压配电系统(交流电压不超过 1 000 V、直流电压不超过 1 500 V)的电气安全 — 保护措施的测试、测量或监测设备 — 第 9 部分:IT 系统绝缘故障定位设备

“insulation fault location system (IFLS)”“绝缘故障定位系统 (IFLS)”

UL 1778 · Ed. 5 · Rev. 2024

Uninterruptible Power SystemsUninterruptible Power Systems(不间断电源系统)

“continuity of an alternating power source”“交流电源的连续性”